The PDUMNH32HVAT 7.7kW SinglePhase 200240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with nonredundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIAstandard 19inch racks and has one IEC 309 32A Blue outlet for connecting a single device or an additional 230V multioutlet PDU with IEC 309 32A Blue plug, such as Tripp Lite’s PDUMV32HV. Dual 10ft. (3.05 m) input cords, each with IEC 309 32A Blue input plug, connect to any two separate primary and secondary input power sources, including outofphase input sources. The PDU constantly evaluates the power quality of both inputs. To ensure connected equipment remains powered, dynamic solidstate (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable. Builtin LX Platform network management interface allows remote access to the PDU for power monitoring, configuration, control and to receive userconfigurable notifications. The Javafree LX Platform HTML5based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. Provides realtime load/current data with billinggrade accuracy (±1 percent). It supports 10/100 Mbps autosensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Primary and Secondary Inputs for Power Redundancy Enables redundant power configurations for network devices with a single input cord or other nonredundant power supply configuration Two IEC 309 32A Blue (2P+E) inputs, each with 10ft. (3.05 m) cord, connect to separate primary and secondary input power sources Any two input power sources are supported for primary and secondary inputs, including outofphase power sources BuiltIn IEC 309 32A Blue Outlet Power a single 32A plugin device or multiple network devices through a connected 32A 200240V multioutlet PDU, such as Tripp Lites PDUMV32HV metered PDU input (sold separately) Automatic Transfer Switching Dynamic solidstate (TRIAC) automatic transfer switching Switches to secondary power source if primary source fails or becomes unstable 15 ms transfer time ensures uninterrupted operation of connected equipment Builtin processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source Touchscreen LCD Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor Advanced Network Monitoring Preinstalled WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations Broad Communications Compatibility Javafree LX Platform HTML5based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH Supports 10/100 Mbps autosensing for optimum communication with an Ethernet network Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. 10/100 Mbps autosensing for communication with 10/100 BaseT networks Mounts Horizontally in 1U of Rack Space Compatible with EIAstandard 19 in. 4post racks and rack enclosures Included PDU4PKIT rail kit adds rear rackmounting support
Brand
- Tripp Lite